choline chloride fuel micro flowmeter
email: porter@microflowmeter.com Shanghai JSN Micro Flow Meter CO.,LTD is aprofessional manufacturer of super micro liquid flow meter, oval gear flowmeter , mass flow meter, spur gear flow meter, gear pump, gear metering pump,etc. industrial automation instrumentation design, manufacturing, sales andservice as one of the high-tech enterprises. The company has gathered manyoutstanding engineering and technical personnel, strong technical force,advanced production equipment, complete detection means, and developed a seriesof rigorous scientific production process. Sound quality assurance system, intheir own efforts and the vast majority of users with the strong support ofcontinuous development and expansion , Has achieved the recognition of theindustry, the products are exported to more than 20 provinces, municipalitiesand autonomous regions, and are widely used in electric power, metallurgy,chemical industry, military industry, oil fields, aviation and other fields.

choline chloride fuel micro flowmeter
Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.
Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

choline chloride fuel micro flowmeter
The Ovalgear flow meter is a volumetric flow meter. The metering chamber is composed ofupper and lower end caps. The shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

choline chloride fuel micro flowmeter
Maintechnical data of JSN micro oval Oval gear flow meter
CX-M2,flow range :0.5~150ml/min,accuracy 0.5%,G1/8"
CX-M3, flowrange:3~300ml/min,accuracy 0.5%,G1/8"
CX-M5, flowrange:5~1000ml/min,accuracy 0.5%,G1/8"
CX-M6, flowrange:0.5~100L/H,accuracy 0.5%,G1/4"
CX-M9, flowrange:6~600L/H,accuracy 0.5%,G1/4"
CX-M12,flow range:0.3~30L/Min, accuracy 0.5%,G1/2"
CX-M25,flow range:0.5~100L/Min, accuracy 0.5%,G1"
What"s the reason for the tiny gear flow meter"s wheels not turning? the reason:1. The filter is clogged.2. Impurities enter the flowmeter and the rotor gets stuck.Treatment measures:1. Clean the filter.2. Check the filter for damage and clean the inside of the flow meter.